Lennox iComfort S30 Installation And Setup Manual page 57

Color touchscreen programmable wi-fi communicating thermostat
Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

®
The iComfort
Equipment Interface Module (EIM) can be configured in the
following setups:
S
®
®
iComfort Wi-Fi
, iComfort
non-communicating (conventional) indoor unit and iComfort
S
®
®
iComfort Wi-Fi
, iComfort
non-communicating (conventional) indoor unit and outdoor unit.
S
®
®
iComfort Wi-Fi
, iComfort
non-communicating heat pump
1. Wiring—See Communicating System and Optional Accessories Wiring
diagrams.
• 4-conductor thermostat wire between the HD Display, Smart-Hub and gas
equipment interface module (R, i+, i-, C)
• 4-conductor thermostat wire from the iComfort
C)
• Up to 8-conductor thermostat wire from the non-communicating furnace
terminal strip to the equipment interface module (R, C, O, Y1, Y2, G, W1, W2
and W3).
• Wiring as required for accessories
2. DO NOT cut any option link on furnace control.
3. After the entire system is wired, power up the system; the iComfort
check the system for installed communication devices.
__________________________________________________________________________________________________________________________________
An outdoor temperature sensor is provided in all iComfort
display the outdoor temperature on the home screen of the HD Display, you can
enable this feature under the dealer control center. Use the following procedure to
enable the outdoor temperature sensor display.
1. Press Menu and then press settings.
2. Press advanced settings and then press view dealer control center.
3. Press equipment and then press thermostat.
4. Press Outdoor Temperature and select sensor. Press the back arrow (<)
at the top left-hand of the screen to return to the dealer control center.
5. Press exit to return the HOME screen.
®
PARTIAL ICOMFORT
SYSTEM — ICOMFORT
Equipment Interface Module with either a
®
Equipment Interface Module with either a
®
furnace, iComfort
Equipment Interface and a
®
S30 to the heat pump (R, i+, i-,
®
outdoor units. To
HOME screen menu icon
®
EQUIPMENT INTERFACE MODULE
4. During the Installer System Setup (see page 14) you will arrive at the
equipment found screen. From there select non-communicating
equipment to add non-communicating equipment.
5. From the add/remove equipment screen, select either 1 Stage A/C unit or
outdoor unit.
2 Stage A/C unit. Press the done to return to the equipment found screen.
Press continue to proceed to the next screen.
6. Continue with the installer setup sequence. When the set up airflow per zone
screen appears here you can adjust blower, heating and cooling circulation air
flows. When done, press continue to proceed.
7. The dealer control center will appear. Press tests to access the test section
8. Here you will have another opportunity to adjust blower circulation, heating and
cooling circulation air flows. Use the plus or minus buttons to adjust up or down
the CFM settings. Once adjustments are completed, press continue.
9. Under the select test to run, you may un-check any test not required, or run
all test. Press start tests to proceed. Once each test section is completed,
press continue to proceed to the next group of test.
10. Once all test are completed, press done. The will return you to the select tests
to run screen. If finish, press the back arrow (<) at the top left-hand of the
®
S30 will
screen to return to the dealer control center. Press exit to return the HOME
screen.
TIPS
6. Press the Home icon at the top left-hand corner of the screen to return to
Home screen.
To enable the Indoor Humidity Display on the Home screen use the following
procedure:.
1. Press Menu and then press settings.
2. Press advanced settings and then press view dealer control center.
3. Press equipment and then press thermostat.
4. Press Display Indoor Humidity and toggle to on. Press the back arrow (<)
at the top left-hand of the screen to return to the dealer control center.
5. Press exit to return the HOME screen.
Turn the Indoor humidity display on and off in a similar manner as above.
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents