AIRFLOW PROFILE - COOLING
Options are:
S
1 - no delays
S
2 - ON: 100% - finish cycle - 45 second delay off.
S
3 - ON: 82% - 7-1/2 minutes at 100% and finish cycle off.
S
4 - ON: 50% - 30 seconds at 82% - 7-1/2 minutes at 100% and finish cycle 50%
/ 30 seconds off.
HIGH HP AIRFLOW
The range is 800 -1100 CFM. Default setting is depending on unit tonnage. Can be
incrementally adjusted by 25 CFM.
Range of operation of the indoor blower during high heat pump operation.
CONTINUOUS INDOOR BLOWER AIRFLOW
The range is 450 to 2150 CFM. Default is dependent on component match-up.
Incremental adjustments are made in 5 CFM.
Range of operation of the indoor blower during continuous blower operation.
HEATING INDOOR BLOWER OFF DELAY
The range is 0 - 10 seconds. Default is 10 seconds with an incremental adjustment
of 1 second.
Heating Indoor Blower OFF Delay (Electric Heat only -Blower runs at continuous
air CFM setting during delay timing period)
HEATING INDOOR BLOWER ON DELAY
The range is 0 - 5 seconds. Default is 0 seconds with an incremental adjustment of
1 second.
COOLING INDOOR BLOWER OFF DELAY
The range is 0 - 30 seconds. Default is 0 seconds with an incremental adjustment of
2 seconds.
COOLING INDOOR BLOWER ON DELAY
The range is 0 - 10 seconds. Default is 2 seconds with an incremental adjustment of
1 second.
HP INDOOR BLOWER OFF DELAY
The range is 0 - 60 seconds. Default is 45 seconds with an incremental adjustment
of 5 seconds.
Heat Pump Indoor Blower OFF Delay (Heat Pump only - Blower runs at continuous
air CFM setting during delay timing period)
HP INDOOR BLOWER ON DELAY
The range is 0 - 30 seconds. Default is 0 seconds with an incremental adjustment of
5 seconds.
RESET AIR HANDLER
Any installer modifications under the air handler tab will be reset back to the factory
defaults if the reset air handler option is used.
ABOUT
This screen provides information on unit code, language supported, equipment
type name, unit model number, unit serial number, unit nominal capacity, number of
heating stages, heating capacity by stage, indoor blower CFM range, control
software revision, control model number, control serial number, control hardware
revision, discharge air temp sensor, outdoor air temp sensor, protocol revision
number, device product level, factory installed transformer, 24VAC average power
consumption, 24VAC peak power consumption, line voltage average power
consumption, line voltage peak power consumption, compatible devices list,
application code memory size and micro-controller part number.
EQUIPMENT NAME
A unique name can be assigned to this component. Name can be up to 29
characters. Name can consist of letters, numbers, special characters and spaces.
CONTINUOUS INDOOR BLOWER AIRFLOW
The range is 450 - 2000 CFM with a default setting based on equipment type
match-up. Adjustments are in increments of 5 CFM
NOTE: All communicating installer parameters default CFM values based on DIP
switch setting (non-communicating value) prior to power up are use and calculated
using the CFM conversion tables and rounded up to closest number on 25 CFM
resolution. Any DIP switch changes made after power up are ignore.
HEATING INDOOR BLOWER OFF DELAY
The range is 6 - 180 seconds with a default setting base on equipment type
match-up. Adjustment are increments of 10 seconds.
25
FURNACE