[711D] License key returning failure
Classification
Maintenance error
Check item
Setting
[711F] License key installation failure
Classification
Maintenance error
Check item
Setting
[71a4] Cryptographic key consistency confirmation failure
Classification
Maintenance error
Check item
Setting
[71aa] Unidentified error during certificate acquisition from sCeP server
Classification
Maintenance error
Check item
Setting
[71aB] Timeout error during certificate acquisition from sCeP server
Classification
Maintenance error
Check item
Setting
45641001TH Rev.1
The one-time dongle license fails to be returned to USB device.
Return the license to the USB device used for installing the license.
Check that the USB device is correctly installed.
Notes:
The GP-1080 IPSec Enabler cannot return to the USB device due to
license problem.
The GP-1070 Overwrite Enabler cannot return to the USB device in
the high security (08-8911: 3).
The one-time dongle license fails to be installed.
Check that the USB device is correctly installed.
Cryptographic key consistency confirmation failed.
Start up the equipment in the following procedure: [3] + [C] + [POWER]
→ 5. Key Backup RestoreThen overwrite the corrupted license key with
a normal one.
Unidentified error occurred during certificate acquisition from SCEP
server.
Check SCEP server and the SCEP setting (automatic) on the Web Page
screen as follows: Web Page Administration → Security → Certificate
Management
Timeout error occurred during certificate acquisition from SCEP server.
Check SCEP server and the SCEP setting (automatic) on the Web Page
screen in the following procedure: Web Page Administration → Security
→ Certificate Management