Adjustment Of The Capacity And Image Quality Of Slimpdf - Oki MB760 Service Manual

Hide thumbs Also See for MB760:
Table of Contents

Advertisement

4.4.11

Adjustment of the capacity and image quality of SlimPDF

The compression quality or the resolution is adjusted to reduce the file capacity of a SlimPDF or
improve its quality.
<Adjustment Mode (05)>
Code
Item to be adjusted
9104
Compression quality of
SlimPDF background
processing
9107
Resolution of SlimPDF
background processing
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes to be adjusted and press the [START] button.
(3) Key in the adjustment value. (To correct a value once keyed in, press the [CLEAR] button.)
(4) Press the [OK] or [INTERRUPT] button to store the value in memory. → The equipment
goes back to the ready state.
(5) Let the equipment restart. Acquire the SlimPDF file and check it.
(6) If the desired image quality has not been attained, repeat step (1) to (5).
4.4.12
Surrounding void amount adjustment
The void amount around the network scanned image is adjusted.
In network scanning, since the void amount is very small in stored images, a shadow may
appear around the scanned image due to the subtle difference in the original sizes. This shadow
can be eliminated by adjusting the setting value.
The setting value is applied to all resolutions and color modes.
<Adjustment Mode (05)>
Code
Item to be adjusted
7489
Surrounding void amount
adjustment
<Procedure>
The procedure is the same as that of  P. 4-15 "4.4.2 Density adjustment".
45641001TH Rev.1
Remarks
The smaller the value, the less the file capacity and the
lower the image quality becomes. The larger the value,
the greater the file capacity and the higher the image
quality becomes.
Acceptable values: 0 to 10 (Default: 5)
The smaller the value, the less the file capacity and the
lower the image quality becomes. The larger the value,
the greater the file capacity and the higher the image
quality becomes.
0: 75dpi
1: 100dpi
2: 150dpi
3: 200dpi
Acceptable values: 0 to 3 (Default: 1)
Remarks
When the value increases, the blank area around the
scanned image becomes wider, and the data on the
image decrease.
Acceptable values: 0 to 255 (Default: 0)
The setting value "1" is equal to 1 dot with 600 dpi. (The
value "24" is equal to approx. 1 mm.)
Oki Data CONFIDENTIAL