Electrical Data - Carrier 59TN6A Installation, Start-Up, Operating And Service And Maintenance Instructions

Carrier 59tn6a two-stage, variable speed multipoise gas furnace
Table of Contents

Advertisement

Table 9
- Electrical
Data
UNIT SIZE
VOLTS-
HERTZ-
PHASE
OPERATING VOLTAGE
RANGE*
TWO-STAGE
ECM FURNACES
UNIT
AMPACITY#
MAXIMUM
UNIT
AMPS
Maximum*
Minimum*
080-14
115-60-1
127
104
8.5
080-14
115-60-1
127
104
8.5
080-20
115-60-1
127
104
13.6
100-22
115-60-1
127
104
13.7
120-22
115-60-1
127
104
13.7
*Permissiblelimitsofthevoltagerangeatwhichtheunitoperatessatisfactorily.
11.5
11.5
17.9
18.0
18.0
MINIMUM
WIRE
SIZE
AWG
14
14
12
12
12
MAXIMUM
WIRE
LENGTH
FT (M):I:
32 (9.8)
32 (9.8)
32 (9.8)
31 (9.4)
31 (9.4)
MAXIMUM
FUSE
OR CKT
BKR
AMPSI"
15
15
2O
2O
2O
# Unit ampacity = 125 percent of largest operating component's
full load amps plus 100 percent of all other potential operating components'
(EAC, humidifier,
etc.) full load amps.
1"Time-delay
type is recommended.
:[:Length shown is as measured
one way along wire path between furnace and service panel for maximum
2 percent voltage drop.
GROUND_
NEUTRAL'
ii
Jq3OX
_
MOUNTING
SCREWS
_"--.
J-BOX
MOUNTING
BRACKET
GROUND
Fig. 31 - Installing
J-Box
(When
Used)
A11299
LINEVOLTAGE
ELECTRIC
DISCONNECT
SWITCH
O
Al1146
Fig.
32 - Field-Supplied
Electrical
Box
on Furnace
Casing
35