CONNECTION
DIAGRAM
SEE RATING PLATE FOF
MODEL PLUG USE
NOTES:
HSI
LO
I
BRN
BRN
o H_LHL_
CAP-
--me
i
i
o_
Qm_
1. If any of the original equipment wire is replaced use wire rated for 105°C.
2. Use only copper wire between the disconnect switch and the
furnace junction box (JB).
3. This wire must be connected to furnace sheet metal for control
to prove lame.
4. Symbols are electrical representation only.
5. Solid lines inside PCB are printed circuit board conductors and
are Rot included in legend.
6. Replace only with a 3 amp fuse.
7. Inductor is used with 3/4 hp and 1 hp ECM Blower motors.
8. Factory connected when (LGPS) not used.
9. Blower off-delay, gas heating selections are (90, 120, 150, 180)
seconds, cooling or heat pump 90 seconds or 5 seconds when
dehumidify call is active.
10. Ignition lockout will occur after four consecutive usuccessful
trials for ignition. Control will auto-reset after three hours.
11. Inducer motor (IDM) contains internal auto-reset thermal overload switch.
12. Any of the 5 wires shown within the NEUTRAL L2 box can be
connected to any terminal within the box.
13. Blower motor (BLWM) is locked rotor overload protected by redundant
electronic control circuits.
SCHEMATIC DIAGRAM
TO115VACFIELD-DISCONNECT SWITCH
K
_L2
EQUIPMENT
GROUND _"
PL31 _ _ _ _1
PL13
_
PLY2 _
_PL12
r
_
nlwM
1
< --4qA
....... )
I rr-e
\
j
EAC
[
_
__ EAO-_
EAC-_
_
FRS2
LS
FRS1
PL1-6
HUM
_
FACTORY P OWER WIRING (115VAC)
JUNCTION T ERMINAL
0
CONTROLTERMINAL
FACTORY C ONTROL WIRING (24VAC)
I
I1_
CONTROLTERMINAL
FIELD CONTROL WIRING (24VAC)
"J'-
FIELD EARTH GROUND
--
CONDUCTOR O NCONTROL
I
_--
_
FIELD WIRING SCREW TERMINAL
/-)7
EQUIPMENT GROUND
--4 e,-, PLUGRECEPTACLE
NC
Air Conditioning ( Adjustable A irflow-CFM)
ILK
BlowerDoorInterlockSwitch,SPST(N,O,)
ACR
Air Conditioning R elay, S PST (N.O.)
IND
Inductor (Note#7)
ACRDJ Air Conditioning R elayDefeatJumper
LED
LightEmitting Diodefor StatusCodes
BLWM
Blower M otor(ECM)
LOPS
LowGas Pressure Switch,SPST(N,O,)
CF
Continuous F an Adjustable A irflow-CFM
LPS
Low-Heat P ressure Switch,SPST N.O.
CAP-f
Capacitor
LS
Lm t Sw tch,Auto-Reset, S PST N,C,
COMMR Communication Relay, S PDT
PCB
PrintedCircuitBoard
CPU
Microproceasor/Cirouitty
PL1
12-Circuit C onnector
DHUM
DHUM Connection24VAC)
PL2
4-CircuitHSI & IDMConnector
EAC-1
EectronoA rC eanerConnect o n
PL3
4-ClmuitECMBLWMConnector
(115VAC 1,0AmpMax,)
PL4
4-CircuitModel P lugConnector
EAC-2
Electronic AirCleanerConnection Common)
PL7
4-CimuitCommunication C onnector
FRS-I,2 Fame-RooutSwitch, M an,Reset, S PST N,C,
PL9
2-CircuitOATConnector
FSE
Flame e-Proving SensorElectrode
PLfO
2-CgcuitHSl Connector
FU1
Fuse, 3 Amp,Automotive BladeType
PLff
12-Circul IDMConnector
Factory Installed
PL12
1-CircuitInductor SpliceConnector
FU2
Fuse or Disconnect
PLf3
5-CircuitBlowerGirl,Connector
GV
GasValve
PU4
4-CircuitBlowerPowerConnector
GVR
GasValveRelay, D PST(N,O,)
SWI-1
ManualSwitch,Status CodeRecall
HPS
High-Heat Pressure Switch, S PST (N.O.)
SWl-2
ManualSwitch,Minimum HeatOnly
HPSR
High-Heat Pressure SwitchRelay, S PST N,C,
SWl-3
ManualSwitch,MWIntHeatRiseAdj.
HSI
HotSurface Igniter(115VAC)
SW1-4
ManualSwitch,Comfort/Effy, Ad,
HSlR
HotSurface IgniterRelay, S PST(N.O.)
SW1-5
ManualSwitch,CoolingCFM/Ton
HUM
24VACHumidifier Connection ( 0,5Amp Max,)
SWf-6
ManualSwitch,Component T est
HUMR
Humidifier Relay, S PST N,O,
SWl-7,8 ManualSwitches, B lowerOff-Delay
IDM
Induced DraftMotor, 2 -Speed, P SC
SW4-1
ManualSwitch, T winningMain(OFF) / Sec,
IDR
Inducer M otorRelay, S PST (N,O,)
SW4-2&3 For FutureUse
IHI/LOR Inducer M otorSpeedChange Relay, S PDT
TRAN
Transformer, 1 15VAC / 24VAC
338308:20]
Rev. E
Al1597
Fig. 64 - Wiring
Diagram
87