Troubleshooting Guide - Carrier 59TN6A Installation, Start-Up, Operating And Service And Maintenance Instructions

Carrier 59tn6a two-stage, variable speed multipoise gas furnace
Table of Contents

Advertisement

co
i
t_
START
IsAMBERLEDstatus light on?
YES
I
s AMBER LED status light blinking
rapidly without
a pause?
1!
NO
I
Is AMBER LED status light blinking
ON/OFF slowly with a combination
of
short and long flashes?
!!
YES
Determine
status code. The status code
is a 2 digit number with the first digit
determined
bythe
number of short
flashes and the second digit by the
number off ong flashes?
,L
Go to section
below for the status
code
that
was flashed.
Troub leshooting
Guide
-_
s there115V
at L1 andL2?
YES
I
Is there 24V at SEC-1 and SEC-2?
_!
YES
Replacefurnace
control.
Is door switch closed?
YES
I"_
I
Is there 115V going to switch?
YES
l
[
Replace d.....
itch.
I__
Check for correct
line voltage polarity.
If
units are twinned,
check for proper low-
voltage (24V) transformer
phasing.
--_
Replace transformer.
To recall previous status codes disconnect
the R
thermostat
connection,
reset power, and put setup
switch BWI-I
in the ON position.
The AMBER LED
will flash the status codes in the order of occurrence.
Record status codes until status code #I I flashes (I
short and 1 long flash).
After status code #11
flashes the status codes will repeat.
Status codes
are erased after 72 hours or can be manually erased
by putting setup switch BW1-1 in the ON position
and jumpering
R, W/W1, and Y/Y2 simultaneously
until status code #11 is flashed.
When done put
setup switch BW1-1 in the OFF position.
,L
Was there a previous status code other
than #I I?
t_
Does the control respond to WA_VI, W2,
Y1, Y/Y2, and G (24V) thermostat
signals?
7! YES
Run system through
a low-heat, high-
heat, or cooling
cycle to check operation.
Status codes are erased after 72 hours
or can be manually
erased by putting
setup switch SWl-1
in the ON position
and jumpering
R, W/W1, and Y/Y2
simultaneously
until status code #I I is
flashed.
I
Replace furnace
control.
1
I
Is door switch closed?
Is circuit breaker closed?
YES
Check for continuity
in wire from circuit
breaker to furnace.
Close circuit breaker and go back to
START.
Check room thermostat
or
interconnecting
cable.
l.o
Is 24V present
at WA,VI, W2, Y1, Y/Y2 or
G thermostat
terminals
on the furnace
control?
I
YES
Disconnect
all the thermostat
wires from
the furnace
control.
l
Does the problem
repeat when using a
jumper
wire?
1.°
The thermostat
is not compatible
with the
furnace
control.
Either install a ballast
resistor,
connect
the Com24V
thermostat
terminal
to the thermostat,
or replace
the
thermostat.
]