Carrier 59TN6A Installation, Start-Up, Operating And Service And Maintenance Instructions page 68

Carrier 59tn6a two-stage, variable speed multipoise gas furnace
Table of Contents

Advertisement

H
IZ®i
SETUP
SWITCH
SWI-1
SWITCH
NAME
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7 & SW1-8
SW4-3
Furnace
Setup Switch
Description
Status
Code
Recovery
Low Heat Only
(Adaptive
Heat Mode when
SW1-2
is OFF)
Low Heat Rise Adjustment
Comfort/Efficiency
Adjustment
CFM per ton adjust
Component
Self Test
Blower
OFF delay
Intermediate
CFM per ton Adjust
NORMAL
POSITION
OFF
OFF
OFF
ON
OFF
OFF
ON or OFF
OFF
DESCRIPTION
OF USE
....... ,,,,,,,,, , ,,,,
I'urn ON to retrieve
up to 7 stored
status
codes
for
iroubleshooting
assistance
when
R thermostat
ead is disconnected.
_Vhen SWl-2
is OFF allows
low heat operation
witf
single
stage
thermostat.
Turn
ON when
using
Ewo-stage
thermostat
to allow
Low Heat operation
Nhen R to W/Wf
closes
and High Heat operation
Nhen R to W/W1
and W2 close.
I'urn ON to increase
Low Heat airflow
by 18
3ercent.
This compensates
for increased
return
ail
Eemperature
caused
with bypass
humidifier.
This
€lso increases
the low heat inducer
speed
15
3ercent.
I'urn ON to decrease
low heat airflow
by 7 percent.
end high heat airflow
10 percent
for maximum
comfort.
I'urn ON for 400 CFM per ton, Turn OFF for 350
_FM per ton. See also SW4.
I'urn ON to initiate
Component
Self Test
for
:roubleshooting
assistance
when
R thermostat
ead is disconnected.
Turn OFF when Self Test is
,'ompleted.
3lower
Off Delay time - adjustable
90 seconds
to
180 seconds.
See table in Adjustments
section
or
"efer to unit wiring
diagram.
&llows
additional
CFM per ton selections
when
Jaed with SW 1-5
325 CFM per ton (nominal)
when SW 4-3 ON and
-3W 1-5 OFF
350 CFM per ton (nominal)
when SW 4-3 OFF and
-3W 1-5 OFF
370 CFM per ton (nominal)
when SW4-3 ON and
-3W 1-5 ON
_,00 CFM per ton (nominal)
when SW 1-5 ON and
-3W 4-3 OFF
See Air Delivery
Tables for model
specific
CFM
_a. static
pressure
1 --
(o
_zO
m
ir-q_
AC
AIR CONDITIONING
(A/C) SETUP SWITCHES
3W 2, AC (Cooling
Airflow)
SETUP
SWITCHES
I-he AC setup switch selects desired
cooling or high stage cooling
(two stage units) airflow.
3ee Air Delivery Tables for specific
switch settings
CONTINUOUS
FAN (CF) SETUP
SWITCHES
1
_zO
m
mF"l
co
CF
i
iSW 3, CF (Continuous
Fan) SETUP
SWITCHES
!The CF setup switch selects
desired
Continuous
Fan Airflow
l-he CF switch position
is the low cooling airflow selection
for two stage cooling units.
Fhe CFM values
in the Air Delivery
Tables for SW 3 settings are the same as SW 2 settings.
!SW 3 cannot be set for airflow higher than SW 2
3ee Air Delivery
Tables
for specific
switch
settings
A11364
A2V96
Fig. 55 - Furnace
Setup
Switches
and Description
(Continued)
d8