Factory-Supplied Installation Parts; Minimum Clearances To Combustible Materials For All Units - Carrier 59TN6A Installation, Start-Up, Operating And Service And Maintenance Instructions

Carrier 59tn6a two-stage, variable speed multipoise gas furnace
Table of Contents

Advertisement

ii
FIRE,
INJURY
OR DEATH
HAZARD
Failure
to follow
this warning
could
result
in personal
injury,
death and/or property
damage.
When
the furnace
is installed
in a residential
garage,
the
burners
and ignition
sources
nmst be located
at least 18 in.
(457 ram) above the floor. The furnace
must be located
or
protected
to avoid damage
by vehicles.
When the furnace
is
installed
in
a public
garage,
airplane
hangar,
or other
building
having
a hazardous
atmosphere,
the furnace
nmst
be
installed
in
accordance
with
the
NFPA
54/ANSI
Z223.1-2009
or CAN/CSA
B149.2-2010.
(See Fig. 5.)
FIRE HAZARD
Failure
to follow
this
warning
could
result
in personal
injury, death and/or property
damage.
Do not install
the furnace
on its back or hang furnace
with
control
compartment
facing
downward.
Safety
control
operation
will
be
adversely
affected.
Never
connect
return-air
ducts to the back of the furnace. (See Fig. 4.)
Location
Relative
to
Cooling Equipment
The
cooling
coil
nmst
be
installed
parallel
with,
or on
the
downstream
side
of the
unit to avoid
condensation
in the heat
exchangers.
When
installed
parallel
with
the furnace,
dampers
or
other
flow
control
must
prevent
chilled
air from
entering
the
furnace.
If the
dampers
are
manually
operated,
they
nmst
be
equipped
with means
to prevent
operation
of either unit unless
the
damper
is in the full-heat
or full-cool
position.
Table
1 - Factory-Supplied
Installation
Parts
DESCRIPTION
Outlet Choke Plate (provided
with 40K BTUH furnaces
only; see Note)
Air Intake Pipe Flange
Vent Pipe Flange
Pipe Flange Gaskets
Sharp Tip Screws (Vent and Inlet Flanges)
Vent Pipe Coupling
Vent Pipe Coupling
Clamps
Pressure
Switch Tube
Rubber Drain Elbow
Drain Tube Clamps
1/2-in.
CPVC to 3/4-in.
PVC Pipe Adapter
Gas Line Grommet
Junction
Box Cover
Junction
Box Base
Green Ground
Screw
Blunt Tip Screws (Junction
Box)
Thermostat
Wire Grommet
Drain Extension
Tube (Z-pipe)
(Provided
separately
in furnace)
QUANTITY
1
1
1
2
10
1
2
1
1
4
1
1
1
1
1
3
1
1
NOTE:
Only used for 40K BTUH
furnaces
from 0-2000
ft. (0 to 610 M) above sea level for total equivalent
vent lengths under
10 ft. (3 M)
Table 2 - Minimum
Clearances
to Combustible
Materials
for All Units
POSITION
CLEARANCE
Rear
0 (0 mm)
Front (Combustion
air openings
in furnace
and in structure)
1 in. (25 mm)
Required
for service
*24 in. (610 mm)
All Sides of Supply Plenum
1 in. (25 mm)
Sides
0 (0 mm)
Vent
0 (0 mm)
Top of Furnace
1 in. (25 mm)
Recommended