VENT PIPE ADAPTER WITH GASKET
INSTALLED ON FURNACE VENT
PIPE IS CUT FLUSH WITH TOP OF
ADAPTER.
ALIGN NOTCHES
IN VENT PIPE
COUPLING
OVER STAND-OFF
ON ADAPTER.
TORQUE
LOWER
CLAMP
15 LB-IN, WHEN REMAINING
VENT PIPE IS INSTALLED, TORQUE
UPPER CLAMP TO 15 LB-IN.
VENT PIPE FLUSH WITH ADAPTER
VENT PIPE FLUSH SHOWING COUPLING
Fig. 43 -
Vent Pipe Flush
with Adaptor
Al1339
Point elbow down towards
back of furnace
12"
256.0 mm
CASING
SIDE ATTACHMENT
COMBUSTION
AIR PIPE
(NON-DIRECT
VENT)
J
TOP PLATE ATTACHMENT
COMBUSTION
AIR PIPE
(NON-DIRECT
VENT)
Fig. 44 - Combustion
Air Pipe Attachment
Al1345