4. Remove
the top unused
rubber
plug from
the port on the
collector
box opposite
the condensate
trap. See Fig.
59.
5. Connect
a field supplied
3/8-in.
(9.5-ram)
ID tube to the
open port on the collector
box
6. Insert a field supplied
funnel into the tube.
7.
Pour
1 quart
of anti-freeze
solution
into the funnel/tube.
Antifreeze
should run through
the inducer
housing,
overfill
condensate
trap and flow to an open drain.
8. Replace
the rubber
plug in the port on the collector
box.
9. Remove
the nfiddle unused rubber
plug from the port on the
collector
box opposite
the condensate
trap. See Fig. 59.
10. Repeat
Steps 5 through
8.
11. If
a
condensate
pump
is
used,
check
with
pump
manufacturer
to verify
pump is safe for use with antifreeze
used.
Allow
pump
to start and pump
anti-freeze
to open
drain.
12. Replace
main door.
13. When
furnace
is re-started,
flush
condensate
pump
with
clear water
to check for proper
operation
before
re-starting
furnace.
14. Propylene
glycol
need
not be removed
before
re-starting
furnace.
3/8-in.
9.6 mm
Fig. 58 - Igniter
Position
- Side View
3/16-in.
4.6 mm
+0.8
2.5 mm_1.5
Al1620
t
Iv
"
to
o o
m
(64.4)
Fig. 56 - Igniter
Position
- Top View
Al1405
Fig. 59 - Priming
Condensate
Trap
Al1392
Burner
Flame
/-
Burner
_2
Fig. 57 - Burner
Flame
Al1461
Fig. 60 - Cleaning
Heat Exchanger
Cell
Al1273
78