Syrup And Water Shutoff Solenoid Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

S
W
YRUP AND
ATER
© 2008-2012, IMI Cornelius Inc.
Step
Action
1
Disconnect power from the unit.
2
Disconnect the CO
3
Remove the rear cover and side panels.
Carefully remove the tubing from the right-angle fitting at the rear of the valve.
4
Be sure not to damage the CO
ure 46).
5
Remove the tubing from the front of the valve.
6
Remove the two (2) locknuts mounting the valve and solenoid to the base.
7
Remove the two (2) mounting screws from the bottom of the mounting bracket.
8
Replace the valve and solenoid.
9
Reverse the procedure to reinstall the valve and solenoid into the unit.
10
Test the unit for CO
11
Replace the rear and side panels.
12
Reconnect power to the unit.
S
S
HUTOFF
OLENOID
The syrup and water shutoff valves and solenoids are mounted on a single
bracket, as shown in Figure 47. Perform the procedure in Table 50. to replace
the valves.
Water
Shutoff
Valves &
Solenoids
Figure 47. View of Shutoff Solenoids w/ Access Panel Removed (2 Barrel Unit)
- 67 -
Table 49.
supply from the unit.
2
metering orfice located above the fitting (Fig-
2
leaks.
2
R
EPLACEMENT
Publication Number: 621260373SER
Viper Service Manual
Syrup
Shutoff
Valves &
Solenoids