Motor Board Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual
M
B
R
OTOR
OARD
Publication Number: 621260373SER
Software
Revision / Board
Description
User Interface - UI
Input/Output - IO
Motor Control
Status
Language Chips
The user interface (UI) board and the input/output (I/O) board must have same
software version for correct operation. If the UI board and the IO board do not
have the same software versions an error will be displayed on the UI. The error
displayed will depend upon which board has 2.x software and has 3.x.Either "X
BRL TEMP OUT" will be displayed or "H20 OUT" will be displayed followed 30
seconds later with "X BRL TEMP OUT". If either of these messages is displayed
after changing a control board check the software version. The current software
version for each board can be found through the menu screen. Select, MENU,
UNIT DATA, then press the "VER" key. The control boards will also have a label
marked with the part number. A -100 suffix has been added to the part numbers
for each of these boards to indicate version 3.0 software release.
The foreign language chips are software version dependent. Part numbers for
software version 3.0 chips have the base number of 629096931 followed by an
alpha suffix designating the language type.
The motor control boards and the main status board will still operate with either
version 2.x or 3.x software of UI and IO board.
When ordering replacement/service parts for any unit check the software ver-
sion of the UI and IO boards and be sure to order the correct board as listed in
Table 60..
EPLACEMENT
When replacing or testing electronic components, be sure to wear a static strap
that is connected to a chassis ground. This protects the electronic components
from any static charge while working on the unit.
The motor board is located in the E-Box, to the right of the control board. It is
mounted to the panel on three (3) plastic mounting studs and a threaded stand-
off, shown in Figure 55.
Step
Action
1
Disconnect power from the unit.
Connect a static strap to your wrist and any convenient chassis ground on the
2
unit.
3
Unplug the eight (8) connectors from the control board.
Table 60.
V2.x Part
V3.x Part
Number
Number
620314871S
620314871-100S
620314869S
620314869-100S
620314868S
620314868S
620314874S
620314874S
629096930XX
629096931XX
Table 61.
- 76 -
Backward
Compatibility
No
No
Yes
Yes
No
© 2008-2012, IMI Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viper 3 flavorViper 4 flavor

Table of Contents