The Viper unit consists of the following systems and hardware:
Multiple freeze barrels, each containing an internal scraper bar driven by an AC
motor.
A refrigeration system and an intelligent, hot gas defrost system.
The components are enclosed in a powder-coated steel frame to prevent
corrosion. It is covered with ventilated cladding panels and a lighted merchandiser.
The cladding is easily removable to facilitate installation, service and
maintenance.
Each barrel has a transparent faceplate, with an integral relief valve and a
removable, self-closing dispensing valve mounted on the front. A removable drip
tray, with cup rest is located directly below the dispensing valves.
A programmable control system with a control panel that controls operational and
diagnostic functions and settings is located behind the merchandiser.
The refrigeration system schematic is shown in Figure 1. It provides the basic
configuration for the Viper refrigeration system.
The wiring diagram of the 2-Barrel Viper unit is shown in Figure 4, the wiring
diagram of the 3-Barrel Viper unit is shown in Figure 5 and the wiring diagram of
the 4-Barrel Viper unit is shown in Figure 6. These diagrams show the details of
the electrical connections in the unit.
- 7 -
Viper Service Manual
Publication Number: 621260373SER