Error Status Menu - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual

Error Status Menu

Publication Number: 621260373SER
Button
BACK
Returns the display to the Select menu
Displays the data for a single barrel, including Outlet Temperature,
Viscosity, if Refrigeration is On or Off, Average Ounces of product
BRL
dispensed per hour for the last three hours and Defrost Lock Time
until next defrost
Displays the real time input voltage and frequency being supplied to
the unit and the low, high or both refrigeration pressures for the unit,
UNIT
depending on the settings of the compressor sensors in the Unit
Data screen, as shown in Figure 36.
Displays the version number of the UI, I/O, Motor and Status boards
VER
installed in the unit
The Error Status menu, shown in Figure 17, displays any current errors contained
in the Error Messages List.
There are three types of errors that can be generated by the system. These error
types and a description of their meaning are listed in Table 5.
Error Type
A System error displays the same information across all barrels in the
System
unit.
Barrel
A Barrel error is limited to a specific barrel
A Limp error is an error that doesn't prevent the unit from operating,
Limp
but limits functionality.
The possible messages from the control system and a description of the errors are
shown in Table 6. The button functions are described in Table 7.
ERROR
STATUS
12:51P
MAR 04
BACK
- 24 -
Table 4
Description
Table 5
Description
#1 MOTOR PWR
COMP HIGH
Figure 17. Error Status Screen
© 2008-2012, IMI Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viper 3 flavorViper 4 flavor

Table of Contents