Installing a New Seal

Publication Number: 621260373SER
Perform the procedure in Table 44., Figure 41 and Figure 42 to replace the bar-
rel seal with a new seal. When installing a new seal, NEVER use oil or silicon
based lubricants. This can cause the new seal to rotate and LEAK!
Step
Action
1
Remove the old seal and the spacer (see Table 43.).
2
Remove the new seal from its packaging.
3
Clean the spacer.
4
Slide the spacer (with slots toward the motor housing) over the motor shaft.
Lubricate the inside of the seal using Dow Corning 111 Lubricant and Sealant.
5
(Note, Do not lubricate the static side(outer portion) of the seal. This could
cause the seal to rotate in the bore and leak.)
Carefully slide the seal over the motor shaft and press it firmly until is fully
6
seated against the spacer and the seal cannot be pushed any further.
Run your finger around the perimeter of the seal to insure it is flush against the
7
back of the barrel.
Reinstall the blade assembly. Rotate the assembly while inserting it to insure
8
that it is fully seated on the motor shaft. (Figure 30)
9
Lubricate the faceplate o-ring.
Re-install the faceplate and replace the four (4) mounting nuts. Hand tighten
the nuts until the faceplate makes contact with the gasket, then use a wrench
10
to tighten the nuts an additional 1/4 turn. Be careful not to overtighten the nuts
or cracking of the faceplate may result.
11
Clean the drip tray and tube using warm water.
12
Perform the seal leak test in Table 45..
Spacer
(Note Orientation)
Motor Shaft
Figure 41. View of Motor Shaft with Spacer on Shaft
- 62 -
Table 44.
© 2008-2012, IMI Cornelius Inc.