Display Board Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual
D
B
R
ISPLAY
OARD
Publication Number: 621260373SER
Figure 53. View of Water Pressure Switch
Step
Action
1
Disconnect power from the unit.
2
Remove the side panel from the unit.
3
Turn off the water supply to the unit.
4
Drain the water from the system.
5
Disconnect the wires from the switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the water supply and check for leaks.
10
Check to ensure that the new switch is working properly.
EPLACEMENT
When replacing or testing electronic components, be sure to wear a static strap
that is connected to a chassis ground. This protects the electronic components
from any static charge while working on the unit.
The display board is located on the back of the control panel display. It is
mounted to the panel with four (4) phillips head screws, shown in Figure 54.
Mounting
Screws
Step
Action
1
Disconnect power from the unit.
Connect a static strap to your wrist and any convenient chassis ground on the
2
unit.
3
Unplug the two (2) connectors from the display board.
4
Remove the four (4) screws from the corners of the board.
5
Replace the board with a new board.
6
Reverse the procedure to install the new board.
Table 57.
Figure 54. View of Display Board
Table 58.
- 74 -
Mounting
Screws
© 2008-2012, IMI Cornelius Inc.