Installing Unit; Installing Leveling Legs; Installing Drip Tray Supports (Item 7) And (Item 8); Installing Drip Tray Drain Hose Kit (Item 10) - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

Locate the Unit so the following requirements are satisfied.
1. Close to a filtered plain water inlet supply line with a minimum water pressure of 12-psig.
NOTE: The FCB Dispenser refrigeration system is equipped with a condenser coil that is cooled by two
condenser coil fans. Circulating air, required to cool the refrigeration system's condenser coil, is drawn
in through the grilled panel on the right-hand side and is exhausted out through the opposite side
grilled panel. Restricting air circulation through the Unit will decrease its cooling efficiency.
2. When installing Unit in it's operating position, do not allow obstructions to block sides, top, and front of the
Unit which will block off cooling air intake to the inside of the Unit. Air flow through the Unit must be present
to provide adequate cooling for the refrigeration system.
CAUTION: Do not place or store anything on top of the Unit.
Locate the Unit to provide the following clearances:
Top of Unit
Back side
Sides
Front

INSTALLING UNIT

CAUTION: This Unit is intended for indoor installation only. Do not install this Unit in an
outdoor environment which would expose it to the outside elements.
IMPORTANT: After Unit has been placed in operating position, make sure it is sitting in a level position
on a surface that provides adequate support and stability.

INSTALLING LEVELING LEGS

Very carefully, tilt Unit up and install LEVELING LEGS (item 13) on four corners of the Unit base.

INSTALLING DRIP TRAY SUPPORTS (ITEM 7) AND (ITEM 8)

1. Install DRIP TRAY SUPPORT, LEFT (item 7) and DRIP TRAY SUPPORT, RIGHT (item 8) on front of the
Unit and secure with SCREWS (item 6). See Figure 5.
2. Place DRIP TRAY (item 9) on drip tray supports.
3. Place CUP REST (item 5) in drip tray.

INSTALLING DRIP TRAY DRAIN HOSE KIT (ITEM 10)

Install DRIP TRAY DRAIN HOSE KIT (item 10) on Unit as instructed in Installation Instructions provided with
the Kit.
PREPARING UNIT FOR CONNECTION TO SYRUP, CO
SOURCES
Route coiled up syrup, CO
, and plain water lines out through the hole provided in the Unit base.
2
, AND CITY PLAIN WATER
2
9
Open (24-inches min.)
0-inches
6-inches (min)
Open
312028000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcb overcounter post-mix dispenser

Table of Contents