Step
Action
11
Measure BRIX
12
Adjust BRIX
13
Clear hose
Set product supply
14
valve
15
Replace access panel
BRIX
#1 OFF
#2 OFF
SETUP
12:51P
MAR 04
BACK    BRIX    STOP
Figure 29. BRIX Setup Screen
Splash Panel
Retaining Screws
Figure 30. Splash Panel Mounting Screws
- 41 -
Viper Service Manual
Table 26
Procedure
Place adequate amount of the product on a
refractometer and read the BRIX value. A target
BRIX reading of 13.0 (+/- 1.0) is normally
desired for sugar-based syrups. Lower values
for some diet syrups can be specified. Check
with the syrup manufacturer if you are not sure.
If BRIX is not within the proper range, adjust the
syrup/water mixture by opening or closing the
syrup valve, shown in Figure 32, and then
retest.
When BRIX measurement is complete, press
the valve on the bottom of the appropriate water
solenoid to flush out the hose before closing the
valve at the end of the hose.
Turn product supply valve back to the (BAR-
REL) position for the barrel you tested. (See
Figure 31)
Replace the hoses and the access panel.
Secure the panel with the two screws removed
in Step 2. This completes the procedure.
Publication Number: 621260373SER