Water Pressure Switch Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

W
P
ATER
RESSURE
© 2008-2012, IMI Cornelius Inc.
Syrup
Pressure
Switch
Figure 52. View of Syrup Pressure Switch and Valve
Step
Action
1
Disconnect power to the unit
2
Remove the appropriate side panel.
3
Turn off the syrup supply to the unit.
4
Drain the syrup from the system.
5
Disconnect the wires on the pressure switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the syrup supply and check for leaks.
10
Check switch operation.
S
R
WITCH
EPLACEMENT
The water pressure switch, shown in Figure 53, is located in back of the water fil-
ter, when viewed from the rear of the unit. Access to the switch is obtained by
removing the left side panel of the unit, when viewed from the rear. To replace
the water pressure switch, perform the procedure in Table 57..
Water
Pressure
Switch
Table 56.
- 73 -
Viper Service Manual
Publication Number: 621260373SER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viper 3 flavorViper 4 flavor

Table of Contents