Output Control Keys - Agilent Technologies 66319B User Manual

Mobile communications dc source
Hide thumbs Also See for 66319B:
Table of Contents

Advertisement

5 – Front Panel Operation

Output Control Keys

Output control keys control the output functions of the dc source.
Voltage
Press this key to access the voltage menu.
Display
1
VOLT <value>
2
VOLT <value>
1
LIMIT <char>
Current
Press this key to access the current menu.
Display
1
CURR <value>
2
CURR <value>
Shift
Res
Press this key to access the resistance menu.
Display
1
RES <value>
Output
Press this key to access the output menu list.
Display
*RST
COUPLING <char>
COMP <char>
PON:STATE <char>
PROT:DLY <value>
RI <char>
DFI <char>
DFI:SOUR <char>
PORT <char>
DIGIO <char>
SENSE:PROT<char>
1
REL:MODE <char>
Protect
Press this key to display protection status.
Display
OVER CURRENT
NO FAULT
Shift
OV
Press this key to access the overvoltage protection menu.
Display
PROT:STAT <char>
Shift
Cal
This key accesses the calibration menu (Refer to Appendix B for details).
1
Notes:
These parameters are explained in chapter 3.
2
These status summary bits are explained in chapter 7.
3
These relay modes are explained in chapter 2
value = a numeric value
char = a character string parameter
'
Use
#
Use
"
Use
48
Command Function
Sets the voltage of output 1 (the main output of all models)
Sets the voltage of output 2
Sets the programmable voltage limit (output 1 shown)
Command Function
Sets the current of output 1 (the main output of all models)
Sets the current of output 2
Command Function
Sets the resistance of output 1 (the main output of all models)
Command Function
Places the dc source in the factory-default state
Couples or decouples output 1 and output 2 (NONE | ALL)
Sets output compensation (HREMOTE | LREMOTE | HLOCAL | LLOCAL)
Select the power-on state command (RST | RCL0)
Sets the output protection delay in seconds
Sets the remote inhibit mode (LATCHING | LIVE | OFF)
Sets the discrete fault indicator state (ON | OFF)
Selects the DFI source (QUES | OPER | ESB | RQS | OFF)
Sets the output port functions (RIDFI | DIGIO | TRIGGER)
Sets and reads the I/O port value (0 through 7)
Enables or disables the open sense lead detect circuit (ON | OFF)
Sets the relay mode for option 521units (DD, HD, DH, or HH)
(applies to both outputs; output 1 shown)
Command Function
Status of the protection features (example shows overcurrent)
Status of the protection features (example shows none tripped)
Command Function
Enables or disables overvoltage protection (ON | OFF)
(
and
to scroll through the menu commands.
&
and
to scroll through the menu parameters.
!
and
to select a digit in a numeric entry field.
1
2
3