(NT) Network Setup – (for firmware version 13.99 and earlier) This command
configures the printer for an Ethernet connection.
Value
A
B
C
D
E
F
G
xxx.xxx.xxx.xxx
(continued)
82
Extended System-Level Command Functions
Parameter
Is the transmission interval for
Gratuitous ARP, where:
x
x = The interval, 0 – 2048, in minutes
Is Network Bios Name, where:
y
y = Up to 16 alphanumeric characters,
no spaces
Transmits the printer's Wired network
communication capability, where x:
0 = Advertises the DUPLEX CAPABILITY
x
set value.
1 = Advertises all possibilities for
DUPLEX CAPABILITY.
Is Discovery (DHCP or Bootp), where a:
a
Y = Enable
N = Disable
Is the communication capability for the
Wired network, where x:
0 = Auto-Negotiate
x
1 = 10Base-T, Half Duplex
2 = 10Base-T, Full Duplex
3 = 100Base-T, Half Duplex
4 = 100Base-T, Full Duplex
Is FTP enable, where a:
a
Y = Enable
N = Disable
Is the Gateway Address, where:
x = 0 to 9
Interpretation
Class Series 2 Programmer's Manual
*
Default Value
0
DMX_[and the last
3 octets (in
hexadecimal) of
the MACM (or
MACO) Address]
0
Y
0
N
000.000.000.000