Datamax E-Class Mark II Programmer's Manual page 76

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

(CH) Communicated Heat Commands – This command causes the printer to
ignore DPL Heat commands; instead, the Heat value is controlled via the menu
setting.
(CL) Continuous Label Length – See <STX>c for command details.
(CO) Column Offset – See Cnnnn for command details.
(CS) Communicated Speed Commands – This command causes the printer to
ignore DPL speed commands; instead, speed values are controlled via the menu
setting.
(CT) Communicated TOF Commands – This command causes the printer to
ignore DPL TOF (Gap, Continuous, and Reflective) commands; instead, the sensor
type is controlled via the menu setting.
(DE) DPI Emulation – This command allows printers with higher resolutions to
emulate lower print resolutions, as follows:
600 DPI can emulate 300 and 203 DPI resolutions; and,
400 DPI can emulate a 203 DPI resolution.
(DK) Darkness – This command adjusts the length of the print head strobe to fine-
tune the HEAT setting.
(DM) Default Module – See <STX>X for command details.