STX KuR
Read Data from RFID Tag
(Direct Mode – UHF Interface – Hexadecimal Data Only)
This command instructs the RFID device to read data from the tag and then place that
data into a replaceable field. It is expected that the tag transponder is within the read /
write distance of the RFID programming device; otherwise, "Void" will be printed in the
text or bar code label field(s).
Syntax:
Where:
Sample:
Data should be at least 16 or 24 characters in length.
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
<STX>KuRaa<CR>
- Field number in which to place the data (must be 01,
aa
02, 03, etc.) matching the order of Label Formatting
command, U.
A 00 value will send the ID to the host with no
printing.
<STX>L
D11
1911A1801000100 xxxxxxxxxxxxxxxx
U
1A31050002000200 xxxxxxxxxxxxxxxx
U
X
<STX>KuR01
<STX>Kur02
<STX>G
The sample above creates a replaceable text field (01) and bar
code field (02) and then recalls the data from the tag and places it
into the specified fields.
121