Stx Kx Delete Configuration File; Stx Kz Immediately Set Parameter - Datamax E-Class Mark II Programmer's Manual

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

STX Kx
Delete Configuration File
This command deletes a configuration file.
Syntax:
Where:
Sample:
STX KZ
Immediately Set Parameter
This command immediately sets the specified parameter.
Syntax:
Where:
Sample:
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
<STX>KxmName<CR>
- Valid Module ID – Range A to Z.
m
- The name, up to 16 characters, of the configuration
Name
file.
- 0x0d terminates the name.
<CR>
<STX>KxYPlant1
The sample above deletes the configuration file Plant1 from
Module Y. (Remember to prefix this command with the Module
(Un)Protect Command <STX>Kp.)
<STX>KZax<CR>
- Valid parameter identifier, as follows:
a
F = Feed Speed
P = Print Speed
S = Slew Speed
H = Heat Setting
- Speed Parameter Range – A to e (see Appendix L).
x
-or-
- Heat Parameter Range – A two-digit value (00-30);
xx
see the "H" Label Formatting Command.
<STX>KZH22
The sample above causes the file currently being executed to
assume a Heat Value of 22.