Datamax E-Class Mark II Programmer's Manual page 109

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

(SP) Serial Port – This command configures the serial communication port(s) as
follows:
Value
xyz
xyzz
For EX2 models the data length, parity, and stop bits are fixed at 8, N, and 1
respectively. And, for Applicator Interface Card-equipped models, this command is
also used to configure the GPIO Auxiliary port (ID always "B").
Example: <STX>KcSPAPB;SPApN;SPAD8;SPAS1;SPAB19<CR>
The example above configures Serial Port A to use hardware and software
handshaking, an eight-bit word, with no parity and one stop bit at 19,200 bits per
second.
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
Serial Port Range / Interpretation
Where:
x = Port Identifier:
A - Serial A
B - Serial B
Where:
x = Port Identifier:
A - Serial A
B - Serial B
Table 5-12: Serial Port Configuration Set Command
y = Function:
P - Handshaking
Protocol
p - Parity
D - Data Length
S - Stop Bits
y = Function:
B - Baud Rate
z = Setting
B - both
H - hardware
N - none
S – software
E - even
N - none
O – odd
7 - eight bits
8 - seven bits
1 - one bit
2 - two bits
zz = Setting:
12 - 1200
24 - 2400
48 - 4800
96 - 9600
19 - 19200
28 - 28800
38 - 38400
57 - 57600
15 - 115200