Stx Kj Assign Communication Port (Mcl) - Datamax E-Class Mark II Programmer's Manual

Class series ii
Hide thumbs Also See for E-Class Mark II:
Table of Contents

Advertisement

Sample:
The process normally adds a few seconds to the power-up sequence; however, if the
printhead is invalid or extremely damaged, it could take a minute to complete.
STX KJ
Assign Communication Port
This command assigns a communication port for specific use. When activating MCL, all
ports are assigned to MCL; this command allows changes to that assignment.
Syntax:
Where:
Sample:
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
<STX>KHB<CR>
The sample above returns results from the last dot check for
the number of elements tested, the number of the bad or
suspect dot(s), the total number of bad or suspect dots, and the
minimum, maximum, and average resistance and variance:
<STX>KJpf<CR>
- Port ID: P = Parallel
p
S = Serial (A)
U = USB
N = Ethernet
L = Wireless
A = Serial (B)
- Flag:
1 = DPL
f
0 = MCL
<STX>KJN1
The sample above forces the Ethernet port to bypass MCL and
go directly to DPL.
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
BAD DOT LIST
143
144
TOTAL BAD DOTS:
2
MIN
MAX
AVG
VAR
921
1640
1125 719
(MCL Command)
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents