Appendix J – General Purpose Input Output Port Applications
Applicator Interface Card (Type 1) GPIO Port (J2) Overview
Pin
Signal
Number
Name
Ground
1
(Configurable)
+5 VDC
2
(Configurable)
Start Of
3
[3]
Print
Slew
4
Label
Pause
5
Toggle
6
Reprint
+24 VDC
7
(1.0 amp
max.)
8
Ground
Ribbon
9
Low
Service
10
Required
End Of
11
Print
Media
12
Out
Ribbon
13
Out
Data Ready
14
(DRDY)
15
Spare
[1]
Evoked by occurrences listed under "Fault Messages" in the A-Class Operator's Manual.
[2]
Reprints the last label exactly, with no increment or time stamp changes; use it for error
conditions. Always keeping this signal LOW will result in non-stop printing.
[3]
If active with no current print job, "WAITING FOR DATA" is displayed. Specifying a quantity of 9999
while always keeping this signal "On" will cause non-stop label printing, except in single label mode
(see Imaging Mode, Section 4.2.5 of the A-Class Operator's Manual), which will cause the printer to
stop between labels.
Class Series 2 Programmer's Manual
Signal
Direction
Ground
Open
Output
Open
Input
Programmable
Input
Programmable
Input
[2]
Input
Output
Ground
Output
Programmable
Output
[1]
Output
Programmable
Output
Output
Output
Output
Active
Jumper
Setting
Placement
Ground
JMP 7 "On"
Open
JMP 7 "Off"
+5 VDC
JMP 8 "On"
Open
JMP 8 "Off"
Low
N/A
Low
+24 VDC
Ground
JMP 9:
Low
Pins 1 & 2
= +5 VDC
– OR –
Low
Pins 2 & 3 =
Low
+24 VDC
Low
N/A
N/A
Function /
Description
Printer chassis ground is
used
Ground return must be
supplied
Printer +5 VDC is used
(.5 amp max.)
+5 VDC must be supplied
N/A
When inactive, all output
pins will be pulled up to
the voltage determined
by this jumper setting.
Failure to
configure the card
for the device(s) you
are connecting may
result in damage to
the printer and/or
the applicator.