(DR) Delay Rate – This command sets the number of minutes to delay between
multiple batch printings of Quick Test Labels.
(DS) Double Byte Symbol Set – See <STX>y or ySxx for command details.
(EM) Input Mode – This command determines the data processing mode:
Value
0
1
3
7
9
(EN) End Character – This command terminates a <STX>Kc string.
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
Interpretation
DPL
Character strings are parsed for standard DPL processing.
No parsing occurs; instead, each carriage return (<CR>)
Line
terminated data line is printed according to a stored template
(see Appendix S).
Character strings are parsed for PL-Z processing, applicable
only if the appropriate firmware is installed, as indicated by a
"Z" in the version string (except for H-Class and M-Class
Mark II, which is standard).
PL-Z
Character strings are parsed for PL-B processing, applicable
PL-B
only if the appropriate firmware is installed, as indicated by a
"B" in the version string.
Character strings are automatically parsed and processed
according to the identified language.
Auto
Input Mode Interpretation
For RFID, the hardware option, tag type and size
should be preselected, and a tag calibration performed.
Also, if possible, driver / software options to use
"Printer Defaults" should be chosen to minimize
potential conflicts.
A clean file is required, where extra leading characters
may cause the language to be unrecognizable;
otherwise, the appropriate Input Mode must be
selected.