Parameter
<STX>Kc
Parameter Name
Pneumonic
Ribbon Low Pause
Ribbon Low Signal
Ribbon Saver Enable
[1]
Row Adjust
Row Adjust Fine Tune
Row Offset
[1]
SOP Adjust
SOP Emulation
(continued)
Class Series 2 Programmer's Manual
Extended System-Level Command Functions
Value /
Range
Y, N
RP
3, 4
RS
A/Y, E, N/D
RE
xxxx dots
RA
+ / – dots
RF
0 – 9999
RO
0 – 255
SA
(128 nominal)
A, L, P, D
SE
Units /
Menu Item (or Number)
Interpretation
Y = Enabled,
N = Disabled
3 = Active Low,
4 = Active High
A or Y = Auto,
E = Enabled,
N or D = Disabled
Model specific; see
Appendix K,
and Row Adjust Fine
Tune
Resolution specific;
see Appendix K.
1/100 in.
N/A,
see Row Adjust Fine
Tune
A = Allegro,
L = Prodigy Plus,
P = Prodigy,
D = Disable
(if available)
Media Settings
Print Options
Printer Options
Print Control (6)
Printer Control
Print Control
N/A
System Settings
Command
Equivalent
N/A
N/A
<STX>R
N/A
N/A
Rnnnn
<STX>O
N/A