7462
9. Remove the three screws (E) securing the operator panel assembly bottom to the scanner frame.
Previous
Next
Go Back
E
10. Slide the flatbed scanner to the rear, and remove.
MPF tray door assembly removal (models X651, X652, X654, and X656)
1. Open the MPF tray door.
2. Carefully pry the left and right manual feeder tabs out of the slots in the manual feed tray.
3. Rotate the manual feeder vertical and pull straight up to remove the feeder.