Field Service Ver. 2.0 Jun. 2010
4.3

Fusing section

4.3.1

Replacing the fusing unit

• The temperature gets high in the vicinity of the fusing unit. You may get
burned when you come into contact with the area. Before replacement
operations, make sure that more than 20 minutes have elapsed since the
main and sub power switches were turned off.
A. Periodically replacing parts/cycle
• Fusing unit: Every 100,000 counts
B. Procedure
1. Remove the rear right cover/1.
See P.34
2. Remove the rear right cover/2.
See P.34
3. Remove the rear cover.
See P.34
1
[2]
[1]
4. PERIODICAL MAINTENANCE PROCEDURE
CAUTION
[1]
[2]
A0XXF2E014DB
A0XXF2E015DA
4. Disconnect the connector (P004) [1]
on the printer control board.
5. Remove the harness from five wire
saddles [2].
6. Disconnect the connector (CN2) [1]
on the DC power supply.
7. Remove the harness from the har-
ness guide [2].