Installation
Installation is in the reverse order of removal.
Pay attention to the following points:
• Apply bond to the mating surface of the breather
cover.
: Sealant 99000–31110 (SUZUKI BOND
No.1215 or equivalent)
NOTE
• Make surfaces free from moisture, oil, dust
and other foreign materials.
• Spread on surfaced thinly to form an even
layer, and assembly the crankcases within
few minutes.
• Fit the breather cover (1) and tighten the bolts.
• Install the regulator/rectifier bracket (2) and tighten the
bolts.
1
Crankcase Breather (PCV) Cover Inspection
Inspect the crankcase breather (PCV) cover in the
following procedures.
1) Remove the crankcase breather cover. Refer to
"Crankcase Breather (PCV) Hose / Cover Removal
and Installation (Page 1B-8)".
2) Inspect the crankcase breather cover in the carbon
deposit. If the carbon deposit is found in the
crankcase breather cover, remove it.
3) Reinstall the crankcase breather cover. Refer to
"Crankcase Breather (PCV) Hose / Cover Removal
and Installation (Page 1B-8)".
I718H1120040-03
2
I717H1120013-01
Emission Control Devices:
B817H21206008
1B-9
I718H1120015-02