Control Cable Installation - BRP Evinrude Installation Manual

Table of Contents

Advertisement

same path to the starboard side of the powerhead.
Secure all cables with clamps.
NOTICE
After installation, make sure there
is enough clearance for all cables to avoid
binding or chafing through all engine steering
and tilting angles.

Control Cable Installation

Refer to Control Cable Identification on p. 51.
Remove control cable trunnion covers and cable
attachment hardware.
1. Trunnion covers
Shift Cable Installation and Adjustment
Place the shift cable on the shift lever pin and
install the washer and retainer clip. Refer to Cable
Retainer Clip Installation on p. 51.
IMPORTANT:
Do not bend or deform clip.
Make sure the remote control, gearcase, shift link-
age, and shift cable are in NEUTRAL.
EVINRUDE E-TEC 90° V MODELS 200–300 HP
Hold the shift linkage in NEUTRAL.
Push and pull on the shift cable and observe the
cable slack. Hold the casing guide in the center of
the slack.
Adjust shift cable trunnion to align with center of
the trunnion block. Place cable trunnion in trun-
nion block.
Install trunnion cover and screw. Tighten screw to
a torque of 60 to 80 in. lbs. (7 to 9 N·m).
003974
1
1. Shift cable retainer clip and washer
2. Shift cable trunnion
Throttle Cable Installation and Adjustment
With remote control lever in NEUTRAL, pull firmly
on throttle cable casing to remove slack.
1
Place throttle cable on throttle lever pin and install
washer and retainer clip. Refer to Cable Retainer
Clip Installation on p. 51.
1
005037
1. Throttle cable retainer clip and washer
OUTBOARD RIGGING
2
005038
003967
53
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents