BRP Evinrude Installation Manual page 83

Table of Contents

Advertisement

Use the Prime Oil System button of the Dynamic
Test screen to prime the oil pump.
1
Dynamic Test Screen
1. Prime Oil System button
Observe oil flow through all oil distribution hoses.
Air must be purged during the priming procedure.
90° V6 Models
1. Oil distribution hoses
60° V4–V6 Models
1. Oil distribution hoses
Make sure that oil flows through the rear oil distri-
bution manifold to the cylinder block fittings.
1. Rear oil distribution manifold
Small bubbles are acceptable. Large bubbles
008570
must be eliminated through continued priming.
1
3
1. Oil distribution hose
2. Small bubbles
1
3. Large bubbles
Repair any fuel or oil leaks.
The oiling system on these models can also be
primed using the Self-Winterizing feature if diag-
nostics software is not available. Refer to Opera-
004224
tor's Guide.
1
004965
FUEL AND OIL PRIMING
OIL SUPPLY PRIMING
008016
2
004398
1
4
81