Idle Speed - BRP Evinrude Installation Manual

Table of Contents

Advertisement

Emergency Stop / Key Switch
Check emergency stop function. With outboard
running at IDLE, pull safety lanyard from emer-
gency stop switch. Outboard must stop immedi-
ately.
Remote Control Operation
Make sure that control can be easily moved into
all gear and throttle settings. Do not shift remote
control when outboard is not running.
Start-In-Gear Prevention
A
WARNING
Make certain that the starter will not oper-
ate when the outboard is in gear. The start-
in-gear prevention feature is required by
the United States Coast Guard to help pre-
vent personal injuries.
Start outboard and shift to FORWARD.
Turn outboard OFF while control is in FORWARD.
Try to restart the outboard. Outboard should not
start.
Shift back to NEUTRAL and restart outboard.
Shift to REVERSE. Turn outboard OFF while con-
trol is in REVERSE.
Try to restart the outboard. Outboard should not
start.
Tachometer Pulse Setting
(SystemCheck)
Confirm accuracy of tachometer reading.
Adjust dial on back of tachometer to required
setting (the outboard should not be running).
Outboard Model
15–300 HP
Tachometer Setting
6 Pulse or 12 Pole
I-Command Set up
Complete basic set up of I-Command gauges.
Configure engine and fuel tank, set fuel tank
capacity etc. Refer to I-Command User's Guide.
Water Pump Overboard Indicator
A steady stream of water should flow from the
overboard indicator.
1. Water pump overboard indicator
Operating Temperature
An outboard run at idle speed should achieve a
temperature based on the engine's thermostatic
control. In general, the powerhead temperature
should reach at least 104°F (40°C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature.

Idle Speed

Make sure the outboard idles within the specified
idle RPM range. If the outboard is run on a flush-
ing device, the idle speed and quality may not be
representative of actual in water use.
Break-In
Evinrude E-TEC outboards require no break in.
When the outboard is delivered, refer the cus-
tomer to the Oiling System information in the
Operator's Guide.
PREDELIVERY
RUNNING CHECKS
1
008469B
85
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents