13
Turn on the MAIN POWER SW. Then, turn on the SUB
POWER SW while pressing the Left, Right and Down
keys to enter the SERVICE MODE.
14
Select [CAP&WIPER CTRL] > [CAP] > [UP], and press
the [ENTER] key to move up the capping unit 1 step.
Check that the GUIDEs at the two ends of the capping
unit align with the GUIDEs at the two ends of the head
carriage. Then press the [ENTER] key twice more to
cap the heads.
15
Clear the PUMP TIMES.
Select [HISTORY MENU] > [MOTOR GROUP] >
[PUMP TIMES] > [CLEAR], and press the [ENTER] key
.
16
Fix the I/S COVER.
[
], [
MENU
SERVICE MENU
GUIDE
SERVICE MENU
HISTORY MENU
[
HISTORY MENU
MOTOR GROUP
[
PUMP TIMES
52134 times
3-28
], [
] + POWER ON
[MENU] key
GUIDE
]
]
PUMP TIMES
CLEAR
I/S COVER