Roland VersaCamm SP-540V Service Notes page 146

Wide format printer
Hide thumbs Also See for VersaCamm SP-540V:
Table of Contents

Advertisement

Pull up the Handle part of the TOOL HOLDER with the
8
DIAL GAUGE (ST-013) and measure the pressure
when the pen tip leaves the BED.
Adjust the parameter in the [30gf] menu with [ ] and
[ ] keys so that the pressure will be 25 ~ 35gf(0.25N ~
0.35N).
Press the [ENTER] key to save the settings.
Select [200gf] under [FORCE ADJUST] menu.
9
Press the [TEST CUT] key and move the TOOL down.
Pull up the Handle part of the TOOL HOLDER with the
10
TENSION GAUGE (ST-002) and measure the pressure
when the pen tip leaves the BED.
Adjust the parameter in the [200gf] menu with [ ] and
[ ] keys so that the pressure will be 195 ~ 205gf (1.9N
~ 2.0N).
Press the [ENTER] key to save the settings.
Enter [30gf] menu under [FORCE ADJUST] menu for
11
checking again.
Press the [TEST CUT] key and move the TOOL down.
ST-013
TOOL HOLDER
SERVICE MENU
FORCE ADJUST
FORCE ADJUST
200gf
200gf
ST-013
TOOL HOLDER
SERVICE MENU
FORCE ADJUST
FORCE ADJUST
30gf
30gf
4-49
30gf
17
16
[
[ENTER]
56
57
[TEST CUT]
200gf
56
57
[
] [
[ENTER]
17
16
[TEST CUT]
] [
]
4
]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents