CODE
MEANING
No.
0111
Tool / Crop
This error occurs when the
Error
machine performs the Auto Crop
Mark Detection or the Auto Print /
Cut adjustment without the Tool /
Crop Mark Sensor Adjustment.
0120
Thermistor
Thermistor of the Print Heater
Error
doesn't work correctly.
(Print Heater)
0121
Thermistor
Thermistor of the Dryer doesn't
Error
work correctly.
(Dryer)
0125
Heater Error
Print Heater doesn't work correctly.
(Print Heater)
Temperature of the Print Heater is
over 60 degree Celsius.
0126
Heater Error
Dryer doesn't work correctly.
(Dryer)
Temperature of the Dryer is over
60 degree Celsius.
CONTENTS
Tool / Crop Mark Sensor Adjustment
has not been performed.
Thermistor of the Print Heater is broken.
There is a cut-line/short in the wiring of
the Thermistor.
Thermistor of the Dryer is broken.
There is a cut-line/short in the wiring of
the Thermistor.
There is a cut-line/short in the wiring of
the Print Heater.
Thermostat is broken.
Thermistor is broken.
There is a cut-line/short in the wiring of
the Dryer.
Thermostat is broken.
Thermistor is broken.
CAUSE
1 ) Tool / Crop Mark Sensor Adjustment
1) Check the wirings of Print Heater
2) Thermistor Replacement
1) Check the wirings of Dryer
2) Thermistor Replacement
1) Check the wirings of Print Heater
2) Thermostat Replacement
3) Thermistor Replacement
1) Check the wirings of Dryer
2) Thermostat Replacement
3) Thermistor Replacement