FP0
1.2

Expansion Possibilities

Be sure to check that the units are added according to the following restrictions:
A maximum of three expansion I/O units or analog I/O units
can be connected to one control unit.
There are no restrictions on the combinations of the kind
control units and expansion units.
A combination of relay output types and transistor output
types is also possible.
The expansion unit can be attached directly to the control unit
easily. Special expansion cables, backplanes, and so forth,
are unnecessary as the expansion unit employs a stacking
system that uses expansion connector and expansion hooks
on the surface of the unit itself.
Control unit
Contollable I/O Points
Type of
Control unit
control unit
only
C10R
10 points
C14R
14 points
C16T/C16P
16 points
C32/T32
32 points
First
expansion unit
Maximum possible expansion is with a total of 3 units
When the expansion unit is
the same output type as the
control unit
max. 58 points
max. 62 points
max. 112 points
max. 128 points
1.2 Expansion Possibilities
Second
Third
expansion unit
expansion unit
When the expansion unit is
a transistor output type
max. 106 points
max. 110 points
max. 112 points
max. 128 points
Overview