Host-to-Switcher Instructions

The switcher accepts SIS commands through its serial ports and/or its LAN port.
SIS commands consist of one or more characters per command field. They do not
require any special characters to begin or end the command character sequence.
Each switcher response to an SIS command ends with a carriage return and a line
feed (CR/LF = ]), which signals the end of the response character string. A string
is one or more characters.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher
is unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)

Using the Command/Response Tables

The command/response table begins on the next page. Except for the gain and
attenuation settings and the filter settings, upper or lowercase letters are acceptable
in the command field. The table below shows the hexadecimal equivalent of each
ASCII command.
ASCII to HEX Conversion Table
Space
N With the exception of the audio gain and attenuation (G and g) and horizontal
ISS 506 Integration Seamless Switcher • SIS
and vertical filtering (D and d) commands, the SIS commands are not case
sensitive.
Programming and Control
4-11