Extron electronics IN1604 DTP User Manual

Extron electronics IN1604 DTP User Manual

Scaling presentation switchers
Hide thumbs Also See for IN1604 DTP:
Table of Contents

Advertisement

User Guide
Scalers
IN1604 DTP
IN1604 HD
Scaling Presentation Switchers
68-2631-01 Rev. A
08 14

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics IN1604 DTP

  • Page 1 User Guide Scalers IN1604 DTP IN1604 HD Scaling Presentation Switchers 68-2631-01 Rev. A 08 14...
  • Page 2: Safety Instructions

    Safety Instructions Safety Instructions • English Инструкция по технике безопасности • Русский WARNING: This symbol, , when used on the product, is intended to ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан alert the user of the presence of uninsulated dangerous voltage within the на...
  • Page 3 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4: Conventions Used In This Guide

    Conventions Used in this Guide Notifications The following notifications are used in this guide: Potential risk of severe injury or death. WARNING: AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information.
  • Page 5: Table Of Contents

    Audio Submenu ..........22 Preset Management Page ......70 Advanced Submenu ........23 General Settings Page ........71 Communication Submenu ......25 Device Info Submenu ........26 Front Panel Lockout (Executive Modes) .... 26 IN1604 DTP and IN1604 HD Scalers • Contents...
  • Page 6 Reference Information ....... 75 Mounting ............75 Tabletop Mounting ........75 Rack Mounting ..........75 Furniture Mounting........76 Downloading Updated Firmware ....... 77 IN1604 DTP and IN1604 HD Scalers • Contents...
  • Page 7: Introduction

    This guide contains information about installing, operating, and configuring the IN1604 DTP Scaler with DTP Extension and the IN1604 HD Scaler with HDMI output. In this guide, the term “IN1604 DTP” refers to the IN1604 DTP Scaler with DTP Extension, “IN1604 HD”...
  • Page 8: Key Features

    The following diagram shows the IN1604 DTP mounted under a table with four inputs and one output. Flat Panel Display MODEL 80 Extron TLP Pro 720T Laptop Tuner 1 2 3 7" Table Top Display Volume Tuner Channel Presets TouchLink Pro...
  • Page 9: Audio

    Selectable output rates — Include computer-video output rates from 640x480 to • 1920x1200, HDTV rates up to 1080p/60, and 2K. Integrated DTP output (IN1604 DTP only) — Supports digital signal transmission of • HDMI or DVI plus control and analog audio up to 330 feet (100 meters) over a single shielded twisted pair cable, providing high reliability and maximum performance on an easily installed cable infrastructure.
  • Page 10 Remote powering of a DTP receiver (IN1604 DTP only) — Provides power to • a remote DTP receiver over the twisted pair connection, eliminating the need for a separate power supply at the remote unit. • DTP 230 and DTP 330 compatibility (IN1604 DTP only) — Enables mixing and matching with desktop and wallplate receivers, as well as other DTP-enabled products to meet application requirements.
  • Page 11: Controlling The Scaler

    USB or RS-232 port. Use the Extron DataViewer utility on the connected device to enter SIS commands. • The Extron Product Configuration Software (PCS) on a computer with a Windows ® operating system. IN1604 DTP and IN1604 HD Scalers • Introduction...
  • Page 12: Installation

    Rear Panel Connections • Connection Details Rear Panel Connections The IN1604 DTP and IN1604 HD have many of the same connectors. Figure 2 shows the different output connectors and the different arrangement of the remote connectors on the scalers. IN1604 DTP 100-240V ~ 0.5 A MAX...
  • Page 13 Figure 5. Audio Output Connector Wiring TP output connector and TP output switch (IN1604 DTP only) — Connect a DTP receiver or HDBaseT-enabled device to the TP output RJ-45 connector to send all signals over a single twisted pair cable (see...
  • Page 14 Tx Rx G Tx Rx the 3 poles labeled “RS-232.” IR Over TP port (IN1604 DTP only) — To transmit and receive IR signals, RS-232 connect a control device to the 5-pole captive screw connector. This port includes only the 2 poles labeled “IR” and shares the ground pole with the...
  • Page 15: Connection Details

    Green Return Y Return L Return Video Return Blue Return Blue Return B-Y Return C Return V Sync Return/ DDC Return DDC Return EDID/DDC EDID/DDC H Sync C Sync V Sync EDID/DDC EDID/DDC IN1604 DTP and IN1604 HD Scalers • Installation...
  • Page 16: Hdmi Connections

    The LockIt bracket can also be used in a stacked formation, as shown below. Side Mounted Stacked Figure 6. LockIt Bracket Mounting Options IN1604 DTP and IN1604 HD Scalers • Installation...
  • Page 17: Twisted Pair Recommendations For Dtp Communication

    Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles. • Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners. • Separate twisted pair cables from AC power cables. IN1604 DTP and IN1604 HD Scalers • Installation...
  • Page 18: Operation

    Menu and Enter buttons — Press this button to enter the OSD menu system, select options, or exit the OSD menu system. Navigation buttons — Press any of the four buttons to navigate the OSD menu system or change values of adjustable features. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 19: Powering Up

    NOTE: The Down button can be used when the OSD is inactive to quickly change the output resolution between several rates. Input selection buttons — Press any of the Input selection buttons to change the selected input. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 20: Menu Overview

    Press the Enter button to accept the new value. Press the Menu button to cancel any pending changes. To exit the OSD menu: Hold the Menu button for 3 seconds to exit the OSD menu. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 21: Quick Setup Submenu

    (see Test Pattern on page 23). The available test patterns are Crop, Alternating Pixels, Crosshatch, Color Bars, Grayscale, Blue Mode, and Audio Test Pattern (pink noise). The default setting is Off. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 22: User Presets Submenu

    Image size and position • Preset name NOTE: To save and recall input presets, use SIS commands (see Preset Commands on page 38) or the Configuration Software (see Preset Management Page page 70). IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 23: Picture Controls Submenu

    Up and Down buttons to adjust the tint of the image. These settings are only applicable to analog NTSC, PAL, and SECAM signals. Detail — Press the Navigation buttons to adjust the detail of the image. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 24: Input Submenu

    Auto-Image and maintain the input aspect ratio. These commands ignore the current aspect mode setting, auto-image the input, and then apply a “fill” or “follow.” IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 25 EDID from a list of factory-supplied EDID or select Match Output to use the output resolution and refresh rate (see Resolution on page 20 for a full list of available resolution and refresh rates). IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 26: Output Submenu

    HDCP notification. Output Resolution — Press the Navigation buttons to change the resolution and refresh rate from the select list. The table on page 21 shows the available resolution and refresh rates. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 27 HDCP-encrypted input is sent to a display that is non-compliant, a green background is displayed with a moving message reading “HDCP Content.” If HDCP notification is disabled or Off, a black or muted output is displayed. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 28: Audio Submenu

    Analog Gain and Attenuation — Press the Navigation buttons to set the gain (in dB) for the applicable analog input. Output Format — Press the Navigation buttons to set the output format. Output Volume — Press the Navigation buttons to set the audio output volume. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 29: Advanced Submenu

    By default, the scaler outputs black video and sync (no sync time-out) with no active input applied. The time-out duration can be set to Never (default) or to any duration from 1-500 seconds. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 30 “true” auto image. NOTE: Overscan is valid only on SMPTE input rates (NTSC, PAL, 480p, 576p, 720p, 1080i, 1080p, or 2K [2048x1080]) and is global for each video format. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 31: Communication Submenu

    — The LED on the corresponding tally output pin to the selected input • Mute Blink blinks when video or sync is muted; otherwise, the LED remains lit. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 32: Device Info Submenu

    Auto-Image. All functions and adjustments can still be made through USB or RS-232 control (see SIS Configuration and Control on page 27 or Configuration Software page 47). The menu system returns to the default menu within 10 seconds. IN1604 DTP and IN1604 HD Scalers • Operation...
  • Page 33: Sis Configuration And Control

    The scaler sends this response when an input is switched or when a new Reconfig signal is detected. • The scaler sends this response when a hot plug event on output HplgO detected. IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 34: Error Responses

    | = Pipe (can be used interchangeably with the character) = Escape W = Can be used interchangeably with the character = Input selection = configurable VGA = HDMI/DVI 1 3 = HDMI/DVI 2 = HDMI/DVI 3 IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 35 = OSD is never displayed, output sync is instantly disabled with no active input = 1 second increments 1-500 = OSD bug never times out, output sync never times out (default) IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 36 = prioritizes the lowest numbered active input = Audio volume -100 to 0 in 1 dB steps (where -100 = -100 DB and 0 = 0 dB; = default) IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 37 On) = Audio output mute = local 5-pole captive screw connector and remote 5-pole remote (DTP) captive screw connector = embedded TMDS audio output IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 38 59.94 Hz 60 Hz 640x480 800x600 1024x768 1280x768 1280x800 1280x1024 1360x768 1366x768 1440x900 1400x1050 1600x900 1680x1050 1600x1200 1920x1200 480p 576p 720p 1080i 1080p 2048x1080 (2K) * = Default output resolution IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 39: Command And Response Tables

    = off or disabled = on or enabled = Auto-Image threshold value (where = black and = white; = default) 0-100 = EDID emulation See the definition on page 32. IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 40 = HDMI/DVI 1 = HDMI/DVI 2 = HDMI/DVI 3 = H/V start = default) 0-255 = Pixel phase = default) 0-63 = Total pixels ± of the default value IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 41 = sink or source detected with HDCP = sink or source detected but no HDCP is present = HDMI input HDCP authorization status = block HDCP encryption = allow HDCP encryption (default) IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 42: Picture Adjustment Commands

    = configurable VGA = HDMI/DVI 1 = HDMI/DVI 2 = HDMI/DVI 3 = Enable or disable = off or disabled = on or enabled = Picture adjustment = default) 0-127 IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 43 = configurable VGA = HDMI/DVI 1 = HDMI/DVI 2 = HDMI/DVI 3 = Horizontal position ±2048 = Vertical position ±1200 X1& = Horizontal size 0-4096 = Vertical size 0-2400 IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 44: Preset Commands

    Brightness Image H/V Size Color Total Pixels Phase Tint H Start Film Mode NOTES: = Text label Up to 16 characters = User presets 1-16 = Input presets 1-16 IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 45: Output Configuration Commands

    = Screen saver status = active input detected, timer not running = no active input, timer running, output sync enabled = no active input, timer expired, output sync disabled IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 46 = on or enabled = Video mute on all outputs = unmute = mute to black = mute all output sync and video = Output rate See the definition on page 32. IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 47: Audio Configuration Commands

    = Audio input gain in dB ( = default) = Audio output mute = local 5-pole captive and remote 5-pole remote (DTP) captive analog audio output = embedded HDMI audio IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 48: Advanced Configuration Commands

    = Audio volume in 1 dB steps where = 0 dB and -100 = -100 dB ( = default) -100 X3& = Audio output format = dual mono = stereo (default) IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 49 = 2.5% (default for YUV, S-Video, and CV) = 5.0% X2& = Aspect ratio setting = fill (default) = follow = Video signal status = video/HDMI signal not detected = video/HDMI signal detected IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 50 = perform video and audio mute = perform video sync and audio mute X4& = Mute LED mode = always on = off when muted = blink when muted IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 51: On-Screen Menu Configuration Commands

    = verbose mode (default for RS-232 and USB connections) = tagged responses for queries = verbose mode and tagged queries = Device name text label up to 24 characters IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 52 = at least one output is muted = at least one output is muted and sync is disabled = DTP output format = DTP format (default) = HDBaseT format IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control...
  • Page 53: Configuration Software

    The control software is compatible with Microsoft Windows operating systems. The software program is available on the Extron website. Installing the Software Figure 20. PCS Download from the Extron Website IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 54: Starting The Software

    Offline device configuration is not supported with the IN1604 DTP and IN1604 HD scalers, but the configuration screens and panels can be still be viewed. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 55: Device Discovery Panel

    ) to sort the category in ascending or descending order. To connect to a device: Click the tab ( Device Discovery Select the desired device ( Click the button ( ). A new device configuration tab opens. Connect IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 56: Offline Device Preview

    New Configuration File Dialog Box (IN1604 DTP Selected) Select the desired device model from the Device Models list (see figure 24, Click the button (see figure 24, ). A new offline device configuration tab Configure opens. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 57: Using The Software

    Figure 26. Device Menu Disconnect This option disconnects the PCS program from the connected device and closes the device tab. From the , select Device Menu Disconnect IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 58: Hardware Settings

    Unit Information tab The Unit Information tab displays basic information about the connected device. Figure 27. Unit Information Tab (IN1604 DTP Shown) Click the button ( ) to close the dialog box. Cancel IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 59: Reset Device

    NOTE: Valid configuration files have a .extz file extension. Click the button to apply the saved configuration settings. Restore Click the button to close the System Backup and Restore window. Close IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 60: Update Firmware

    . The About This Device About This Module... Module dialog box opens. Figure 31. About This Module Dialog Box Click the button to close the dialog box. Close IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 61: Software Menu

    Software Settings Dialog Box Click the button. The dialog box closes and the Re-enable Confirmation Dialogs reset is complete. Click the button to close the dialog box without re-enabling Close the confirmation dialogs. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 62 If necessary, click the button to disconnect the software Close Session(s) and Exit from connected devices, close all offline device tabs, and close the software. Click the button to leave the software open. Cancel IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 63: Av Controls Panel

    Sync Mute along with the Video Mute button when enabled. To unmute any signal, click the appropriate button. The button reverts to the default color, indicating the signal has been unmuted. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 64: Configuration Pages

    To open this page, click the icon ( ) on the Global Navigation Bar. Input/Output Config It contains panels for individual input configuration, output configuration, switch transitions, and test pattern generation. Figure 39. Input/Output Configuration Page IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 65 Disable HDCP Authorized to allow the output of the scaler to remain unencrypted. To enable automatic 3:2 and 2:2 film pulldown detection for NTSC, PAL, SECAM, and 1080i input signals, select the check box ( Film Detect IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 66 To aid display device setup and optimization, select a test pattern from the drop-down menu ( ) in the Test Patterns panel. Figure 42. Available Test Patterns NOTE: No input signal is needed when using a test pattern for display device setup. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 67: Edid Minder Page

    ), select a specific resolution Resolution From the drop-down menu ( ), select a specific refresh rate or Refresh Rate Click the button ( ) to remove any active filters. Clear IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 68 Save to EDID Library Click the button to save the file. NOTE: Saving a factory scaler EDID exports an HDMI, LPCM-2Ch EDID to the PC. The file is saved as a .bin file. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 69: Image Settings Page

    (ignores aspect ratio setting). • Click the button ( ) to perform a one-time Auto-Image and to Auto-Image & Follow maintain the aspect ratio of the input signal (ignores aspect ratio setting). IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 70 Auto Phase routine (YUV and RGB only) and centers and sizes the input. Figure 47. Overscan Panel For each input signal type, select a value from the corresponding drop-down menu. NOTE: Setting a value of disables overscan for the corresponding input format. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 71 NOTE: User presets can be saved on one input resolution and recalled on a different one. Input presets can only be recalled on the same input resolution that was present when the preset was saved. Figure 48. Input and User Presets Panels IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 72: User Presets

    ), select the desired preset. Click the button ( ). The Presets dialog box opens. Clear Click the button to erase saved data. Click the button to return to the Clear Cancel Image Settings page. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 73: Size And Position Page

    (ignores aspect ratio settings). Click the button ( ) to perform a one-time Auto-Image and to • Auto-Image & Follow maintain the aspect ratio of the input signal (ignores aspect ratio settings). IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 74: Audio Configuration Page

    — The digital input is configured to receive multi-channel audio. If • Multi-Ch multi-channel audio is not available, 2-channel LPCM audio is passed to the digital outputs. This option sets Multi-Ch audio EDID. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 75 <Tab> key to apply the change. Click the arrow button to the right of the level text field to respectively • Down increase or decrease the level in 1 dB increments. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 76: Preset Management Page

    ) located in the same Input Presets or User Presets Recall Preset panel. A confirmation dialog box opens. Click the button to recall the preset or click the button to return to the Recall Cancel Preset Management page. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 77: General Settings Page

    58) on the Global Navigation Bar to open the Settings General Settings page. Figure 52. General Settings Page To access the dialog box, click the Hardware Settings button. Hardware Settings IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 78 — Displays a black or muted screen when an encrypted source is sent to a Black display that is not HDCP-compliant. — Displays a green screen when an encrypted source is displayed on a sink that • Green is not HDCP-compliant (default). IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 79 Priority to the highest active input number the input to the highest numbered active input. — Automatically switches the • Priority to the lowest active input number input to the lowest numbered active input. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 80 DVI trials, but only encrypted when required. • — The digital output is Always Encrypt Output (with continuous DVI trials) always authenticated and encrypted, with continuous DVI trials. IN1604 DTP and IN1604 HD Scalers • Configuration Software...
  • Page 81: Reference Information

    1U Universal Rack Shelf 1/2 Rack Width Front False Faceplate Front false faceplate uses 2 screws. (2) 4-40 x 3/16" Use 2 mounting holes on Screws opposite corners. Figure 58. Half Rack Shelf Mounting IN1604 DTP and IN1604 HD Scalers • Reference Information...
  • Page 82: Furniture Mounting

    Go to www.extron.com, for a list of available furniture mounting kits. To install the scaler to furniture, follow the mounting kit instructions. Mounting Screws (2) Places Each Side #8 Screw (4) Places Each Side MBU 125 Mounting Bracket Figure 59. Under-Desk Mounting IN1604 DTP and IN1604 HD Scalers • Reference Information...
  • Page 83: Downloading Updated Firmware

    From the left sidebar, click the link ( Firmware Navigate to the IN1604 DTP or IN1604 HD ( Ensure the available firmware version is a later version than the current one on the device. NOTE: The firmware release notes provide details about the changes between different firmware versions.
  • Page 84: Extron Warranty

    Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America,...

This manual is also suitable for:

In1604 hd

Table of Contents