Specific problems
The table below shows some common operating problems and their solutions.
Problem
No image appears.
The image is flashing. The scaled output
Cause
The input signal is
incompatible.
The input is improperly Use the Input Format submenu
configured.
Freeze mode was
entered via an SIS
command when the
image was black.
The scaled output
rate is too high for
the display.
rate is too high for
the display.
The detail level
needs to be
changed.
ISS 506 Integration Seamless Switcher • Operation
Solution
Connect an input device that is
compatible with the ISS.
to select the correct input format.
Deactivate freeze mode via an SIS
command.
Change the scaled output to a
compatible resolution.
Change the scaled output to a
compatible resolution.
The image is too soft.
Use the Filter button to change the
detail level.