Extension User Name - Comdial DX-80 Installation & Maintenance Manual

Table of Contents

Advertisement

Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing "DX-80" at the DOS prompt in the PC-DBA working directory and then pressing
«
.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
¢£¤¥
Use
to highlight "Extension." Then press
¢£¤¥
Use
to highlight "Category 4" and then press
No. Swapping) displays. The cursor is positioned on the first digital extension port.
¢£¤¥
Use
,
«
.
Press
Input the new directory number for this extension. (Note: The directory number must be a valid Extension
Directory Number as allocated in System Applications – Numbering Plan 2.)
«
Press
to invoke the swapping of directory numbers. If this directory number was in use at another
extension port, that port is immediately reassigned the directory number previously assigned to the port
where the swap was invoked.
Continue swapping extension directory numbers as required.
When you have completed all changes, press the
screen. You will see the prompt: "Exit This Feature"; press "Y" for yes.
You will then be prompted to "Save Current Setting?"
Press "N" to abort changes and leave all data unchanged.
Press "Y" to save changes.
If you press "Y" (yes), you will then be prompted "File Exists, Override?"
Press "N" to abort changes and leave all data unchanged.
Press "Y" (yes) to continue with the save operation.
°
Press
(escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a "SEND" function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.

Extension User Name

An alphanumeric, seven-character title may be assigned to each extension in the system. This title will be displayed
on the Digital Speakerphone in place of the standard "EXT" message.
Extension user names are programmed in the customer database programming. The names may consist of upper
and lower case letters and numbers and various "special" characters as provided by the Enhanced Lettering Scheme
feature selection.
Related Features
Enhanced Lettering Scheme
P7290 IMM
DX-80 I
NSTALLATION AND
³´
to highlight the extension port to be changed.
M
M
AINTENANCE
ANUAL
«
.
«
.
«
. The Extension – Category 4 screen (DIR
°
(escape) key to exit this database programming
Intercom Calling - Non Blocking
3-128

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents