CO Line Ring Type Assignment

The DX-80 system provides eight types of ringing for indication of specific CO Line ringing. Any CO Line may be
allocated one of the available Ring Types. When this feature is used, the specific ring type assigned to the CO Line is
the ring type heard when that CO Line rings. This feature is helpful when CO Lines are arranged into groups for
specific call handling. The Ring Type indication helps to identify the CO Line and the group to which it belongs.
Related Features
Distinctive Ringing – Extension
Related Programming
CO Line – CO Line Ring Type
Conditions
a)
CO Line Ring Type overrides Extension Ring Type settings.
b)
When a CO Line Ring Type is set to "0," the Extension Ring Type is used.
Default Settings
All CO Lines are assigned Ring Type 0. (Range is 0-8.)
Programming Abstract
Program CO Lines for the Ring Type.
Programming via the DET (Digital Extension Terminal)
back
next
Note: [
], [
], [
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code
++++++++
"
show
Press [
]. The DB Item Select screen displays.
Input 02-740~755-11 (740~755 = the CO Line directory number).
chg
Press [
] until the appropriate Ring Type displays.
Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing "DX-80" at the DOS prompt in the PC-DBA working directory and then pressing
«
.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press
¢£¤¥
Use
to highlight "CO Line." Then press
¢£¤¥
Use
to highlight "Category 2." Then press
¢£¤¥
Use
to highlight the Ring Type for the CO Line.
«
Press
until the appropriate Ring Type displays.
¢£¤¥
Use
Repeat the programming process for all CO Lines.
P7290 IMM
DX-80 I
NSTALLATION AND
show
chg
bksp
], [
], [
], and [
." (Note: This eight-character password can be changed.)
to highlight the next CO Line Ring Type to be changed.
M