Programming; Communication And Reports Setting - Bosch AMAX panel 4000 Installation Manual

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
9

Programming

The control panel programming options are stored in a non-volatile flash memory. This
memory has all relevant configuration and user-specific data even after a total power loss.
Because the data retention time is quite long without power, reprogramming is not required
after powering up the control panel.
Programming with keypad is possible only when all of zones in the system are in disarmed
status and no alarm is activated. Installer Code is required for programming.
Notice!
It is not recommended to use other keypads or methods simultaneously to program the
system while programming with the current keypad.
9.1

Communication and Reports Setting

Report Options
Telephone Number / IP Address and Port for Receiver 1
Subscriber ID Number
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
Acknowledge Wait Time for Receiver (05 - 99 seconds )
Network Polling Time for Receiver (001 - 999 minutes )
Telephone Number / IP Address and Port for Receiver 2
Subscriber ID Number
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
Acknowledge Wait Time for Receiver (05 - 99 seconds )
Network Polling Time for Receive (001 - 999 minutes)
Telephone Number / IP Address and Port for Receiver 3
Subscriber ID Number
Transmission Format for Receiver (0 = Not used, 1 =
Contact ID, 2= SIA, 3 = Conettix IP)
Anti-replay for Receiver (0 = Disabled, 1 = Enabled)
Acknowledge Wait Time for Receiver (05 - 99 seconds)
Network Polling Time for Receiver (001 - 999 minutes)
Telephone Number / IP Address and Port for Receiver 4
Subscriber ID Number
Bosch Sicherheitsysteme GmbH
Installation Guide
Programming | en
Address
Default
0000 - 0016
15
0017 - 0022
000000
0023
1
0024
1
EN=1
0025 - 0026
05
0027 - 0029
001
0030 - 0046
15
0047 - 0052
000000
0053
1
0054
1
EN=1
0055 - 0056
05
0057 - 0059
001
0060 - 0076
15
0077 - 0082
000000
0083
1
0084
1
EN=1
0085 - 086
05
0087 - 089
001
0090 - 0106
15
0107 - 0112
000000
2013.07 | 03 | F.01U.267.112