5.2.3

Tamper

Each DX2010 module has an onboard tamper and one tamper input, not belonging to zone
inputs.
When the tamper event of DX2010 module occurs, the tamper report is sent with the module
address.
5.2.4

Address Setting

Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
Each DX2010 module connected to the alarm control panel must have its own data bus
address. Refer to following Table for information.
Module
DX2010 module 1 (zones 17 - 24)
DX2010 module 2 (zones 25 - 32)
DX2010 module 3 (zones 33 - 40)
DX2010 module 4 (zones 41 - 48)
DX2010 module 5 (zones 49 - 56)
DX2010 module 6 (zones 57 - 64)
Table 5.4: DX2010 Address Settings
For Address DIP switch settings, refer to the followingTable.
DIP Switch
Data Bus Address
103
104
105
106
107
108
Table 5.5: DX2010 DIP Switch Settings
Bosch Sicherheitsysteme GmbH
S1
S2
32
16
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Installation Guide
Optional Modules and Peripheral Devices | en
Data Bus Address
103
104
105
106
107
108
S3
S4
8
4
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On
15
S5
S6
2
1
On
Off
On
On
Off
Off
Off
On
On
Off
On
On
2013.07 | 03 | F.01U.267.112