138
en | Programming
Keypad Lockout
Address 0499
0 = disabled 1-15 times
Quick Arming
Address 0500
0 = disabled 1= Enable
Display and Prompt Tone of Date and Time Fault
Address 0501
0 = disabled 1= Enable
Fault Prompt Tone
Address 0502
0 = disabled 1= Enable
Printer Functionality
Address 0940
0 = disabled 1= Enable
RF Receiver
Address 0941
0 = disabled 1= Enable
RF supervision
Address 0942
0 = disable 1 = 1h 2 = 2h 3 = 4h 4 = 12 h 5 = 24h
6 = 2.5h
RF Jam Detect Level
Address 0943
0-15 0 = most sensitive
RF Device Low Level Battery Resound
Address 0944
0 = disable 1 = 4h 2 = 24h
2013.07 | 03 | F.01U.267.112
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Address
Default
0499
10
VDS-A
EN=10
Address
Default
0500
1
VDS-A EN=0
Address
Default
0501
0
VDS-A EN=1
Address
Default
0502
1
VDS-A EN=1
Address
Default
0940
0
Address
Default
0941
0
Address
Default
0942
4
Address
Default
0943
12
Address
Default
0944
2