Bosch AMAX panel 4000 Installation Manual page 61

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
11 - AC Power Supply Fault
This output operates when a AC MAINS fault occurs.
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till the AC MAINS power is
restored and fault is reset.
12 - Low Battery
This output operates when a Low Battery fault occurs.
The Dynamic Battery Test is performed every 4 hours after the system is powered up and
every time the system is armed.
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till battery is restored and fault
is reset.
13 - Tamper
This output operates when a Tamper condition occurs.
The output is reset:
1.
lf this duration is programmed as 000, the output will continue till the Tamper condition is
Restored and Tamper is reset.
14 - External Fault
This output operates when an External Fault occurs.
The output is reset:
1.
lf this duration is programmed as 000, the output will continue till the External Fault is
Restored and the fault is reset.
15 - All Faults
This output operates when a Fault occurs.
The output is reset:
1.
lf this duration is programmed as 000, the output will continue till the Fault is Restored and
the fault is reset.
16 - Fire Alarm
The output is triggered when Fire Alarm.
17 - Fire Reset
The output is triggered when Fire Reset.
18 - AWAY Armed
This output operates when System is AWAY Armed.
The output is reset:
1.
Bosch Sicherheitsysteme GmbH
When the AC power supply is restored and fault is reset.
When the output programmed duration is up.
Only after a Dynamic Battery Test report that the backup battery voltage is normal and
fault is reset.
When the output programmed duration is up.
When the output programmed duration is up.
When the output programmed duration is up.
When the output programmed duration is up.
When the output programmed duration is up.
Installation Guide