Address Setting; Wiring - Bosch AMAX panel 4000 Installation Manual

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

26
en | Optional Modules and Peripheral Devices
5.6.3

Address Setting

Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
The receiver address option must have setting, Receiver #1.
AMAX panel 4000 supports Receiver 1 only, Receiver 2 is not supported.
Address Jumper
Figure 5.20: Address
5.6.4

Wiring

Connect RF3227E receiver to Bosch option Bus 1 or 2. The cable may not exceed 300 m.
Adding additional devices to the bus might reduce the maximum distance. Shielded cable is
not required. Do not use twisted pair wire.
RF3227E
Figure 5.21: Connecting RF3227E
2013.07 | 03 | F.01U.267.112
R
B
G
Y
ADDR
Alarm Control Panel
Yellow
Green
Black (-)
Red (+)
Installation Guide
No Jumper = Receiver # 1 (Default)
Jumper left on pin for storage only.
Jumper = Receiver # 2
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitsysteme GmbH
EN